Environmental Monitoring Temp-485-Pt100, RS485, Temperatur Sensor / Sensoren, Temperatursensor, Temperatursensoren, Temperature probe
|
| |
|
|
|
|
| |
Temp-485-Pt100 is a converter/thermometer, which converts temperature from a sensor (Pt100 and Pt1000) to communication protocol over RS-485 busbar. The sensor can be used separately but it is designed for connection to the Poseidon measuring unit.
Temp-485-Pt100 communicates over 4-conductor busbar. To one busbar it's possible to connect parallely up to 31 sensors. The busbar uses 4 conductors, two with a standard RS-485 line (up to 1200 m), the other two are intended for powering sensors.
* Converter: Signal from Pt100 is transferred to RS-485. Thermal sensor is usually located outside the converter box.
* Thermometer: Contains both thermal (Pt100) sensor and converter to RS-485.
The product signature Temp-485-Pt100 covers several device versions, as listed below, that are available. They are mostly converters (Pt100 to RS-485), because a thermal sensor is located outside the device unit. The "Box" version contains the thermal sensor on a box, which means it represents whole thermal sensor. |
| |
 |
|
Temp-485-Pt100 „Box“ version
The thermometer consists of a box for wall mounting, which contains the RS-485 converter / temperature sensor and the Pt100/A sensor itself. The thermal sensor is assembled on the top of the rod on the plastic box with IP65 shielding protection. |
| |
|
|
 |
|
Temp-485-Pt100 „Cable“ version
The thermometer consists of a box for wall mounting containing RS-485 converter / thermal sensor. The Pt100/A sensor itself is attached on a 2m long cable and is a part of the shipment. |
| |
|
|
 |
|
Temp-485-Pt100 „Head“ version
The „Head“ version is a converter unit of the temperature monitored by an external thermal sensor to the RS-485 data bus. The converter's mechanic construction is intended for mounting to a unified "B" thermometer's head. For thermometer's construction it is necessary to connect an external Pt100 thermal sensor - platinum sensor (not part of the shipment) which is connected by two or three conductors. |
| |
|
|
 |
|
Temp-485-Pt100 „DIN“ version
The „DIN“ version is a converter unit of the temperature measured by an external thermal sensor, to the RS-485 data busbar. The converters mechanic construction is intended for mounting to a DIN molding.
For thermometer's construction it is necessary to connect an external Pt100 thermal sensor - platinum linear sensor (not part of the shipment) which is connected by two or three wires. |
| |
|
|
 |
|
Temp-485-2xPt100 „DIN“ version
The unit is identical to the Temp-485-Pt100 „DIN“ version but allows connection of two external Pt100 thermal sensors to a single unit. One box therefore responds at two different addresses at the RS-485 line. |
| |
|
|
 |
|
Pt100 - the PT30 type
Individual Pt100 thermal sensor for connection to converters. PT30 contains a thermal sensor in a metal rod made of stainless material and is connected by a four-wire cable with a teflon insulation, metal covering with silicone insulation |
| |
|
|
 |
|
Temp-485-Pt100 version „Frost“
Temperature probe for extremely low temperature measurements, equivalent to "Cable" version. The probe for measurements from -190°C and connecting cable are part of the supply. |
|
| |
| Temp-485-Pt100 uses for temperature measuring a standard platinum thermal Pt100 sensor. The thermal sensor can by either a mechanical part of a thermometer in a measuring stem or external sensor, connected by two or three wires. |
| |
Application
* Industrial measuring systems with accurate temperature measuring.
* Refrigerator measuring systems with embedded thermal sensors
* Accurate temperature measuring in wide range
* Wide measuring systems with lots of measuring points
* Climatization state measuring and measuring of living conditions in intelligent buildings
* Independent measuring in food warehouses and agricultural crops storage buildings
* Grocery storehouses and premises, hard measuring conditions..
* Thermal and humidity monitoring in pharmaceutical storages
* After connection to Poseidon (all models with RS485 bus) – temperature transmission over Ethernet or Internet
* After connection to Poseidon models 2XXX – possible logging of up to 100 000 values into internal Flash memory. |
| |
Basic properties
* Temperature measuring within the range of -55°C to +640°C
* Measuring accuracy cca ± 0,2°C (± 0,3°C if the „Head“ and „DIN“ versions are not calibrated with actual thermal sensor .
* Possible connection of one or two external Pt100 or Pt1000 sensors (Pt100 / Pt1000 defined by model - ask for more)
* External Pt100 thermal sensors can by connected by two or three conductors.
* Each sensor is tested and calibrated from factory, at extra cost it's possible to supply calibration protocols
* Up to 31 sensors parallely at one busbar
* Suitable for factory environment, RS-485 line communication (up to 1000m distance)
* Minimal power consumption, possible power supply by unstabilized voltage.
* The sensors works with SNMP thermometer Poseidon |
| |
| |
|
|
Ansprechperson |
DANKE das SIE uns besuchen.

DI (FH) Günther Lugauer
Beratung & Verkauf
Technik & Installation
HIER finden Sie meinen
Kompetenzbereich
guenther.lugauer[a]bellequip.at
Tel: +43 (0) 2822 33 33 996
Mobil: +43 (0) 664 33 33 996
BellEquip Zentrale:
Tel: +43 (0) 2822 33 33 990
Fax: +43 (0) 2822 33 33 995
info[a]bellequip.at
www.bellequip.at
Serverschrank Monitoring
Serverraum Monitoring
Rack Monitoring
Environmental Monitoring
Temperatur Überwachung
Serverrack Überwachung
Remote Monitoring
Potentialfreie Kontakte überwachen
Relais über IP
Relay over IP
Rack Monitoring
Remote Power Management
Secure Console Server
Device Server
Terminal Server
Serielle Lösungen
Datenkommunikation
Netzwerktechnik
GSM / GPRS / EDGE
UMTS / HSDPA
Wireless Communication
|
|